| Item | Specification |
|---|---|
| Model | B51.02C |
| Dial size | 40 mm [1.5"] |
Executive standard | ASME B40.100, GB/T 1226 |
| Mounting | Back mount (axial) |
| Lens | PC / 372 |
| Lens seal | / |
| Case | ABS plastic |
| Bezel | / |
| Movement | Brass alloy |
Measuring element | Tin-phosphor bronze; C-type tube |
| Liquid filling | / (dry) |
| Shock rating | V.H.3 |
| Protection rating | IP54 |
| Accuracy | ±4.0% (Class 4) |
| Reference ambient temperature | +20 °C [+68 °F] |
| Temperature error | Per 10 °C (18 °F) deviation, full-scale accuracy error increases ≤ 0.4% |
| Operating ambient temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
| Dial | Aluminium alloy, white background, single or dual scale |
| Pointer | Black aluminium pointer |
| Connection standard | ANSI/ASME B1.20.1, EN 837-1 |
| Connection thread | M10×1, M10×0.75, M8×1 male, quick-connect, others customizable |
| Connection material | Plastic |
| Constant pressure | ≤ 3/4 × F.S |
| Fluctuating pressure | ≤ 2/3 × F.S |
| Short-time shock pressure | ≤ 1 × F.S |
| Service life | 1-3 years; single-use, replace when damaged |
Inflation tools
Everyday low-precision pressure indication
General equipment status indication
Supports batch supply and customized configurations. Example: B51.02C A M1 PC 150 P /B.

Send us your specifications — ranges, connections, materials and volumes.